mxu 500 irs efi Manuale-dofficina : Pagina 44

Microfiches
Image preview

Pagina 42

Image preview

Pagina 43

Image preview

Pagina 45

Image preview

Pagina 46

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          3. INSPECTION/ADJUSTMENT                                          MXU 500 IRS


 3. Loosen the screw (3) and remove the air
    cleaner assembly (4) from the air cleaner
    housing.
 4. Unscrew the clamp (5)




 5. Remove the outer air cleaner (7).
 6. Remove the screw/washers (6) and
    remove the air cleaner assembly from the
    air cleaner holder (8).
 7. Remove the inner air cleaner (9) and air
    cleaner screen (10) from the air cleaner
    guide (11).
 8. Remove the air cleaner screen from the
    inner air cleaner.

 CLEAN AIR FILTER ELEMENT
                                                (7)   (8)   (9)    (10)   (11)
 Wash the element gently, but throughly in
 solvent.
 Use parts cleaning solvent only. Never
   use gasoline or low flash point solvents
   which may lead to a fire or explosion.

 Squeeze the excess solvent out of the
 element and let dry.
 Do not twist or wring out the foam
   element. This could damage the foam
   material.

 Apply the engine oil.
 Squeeze out the excess oil.
 The element should be wet but not
   dripping.

 More frequent replacement is required when
 riding in unusually dusty or rainy areas.

                                                                          3-6