1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          7. ENGINE REMOVAL/INSTALLATION                                               MXU 500 IRS

                                              Breather Hose
 Disconnect the breather hose from cylinder
 head cover and remove the mounting nut
 from breather housing holder, then remove
 the breather housing.




                                              Vacuum Hose       Starter Cable
 Disconnect the vacuum hose from intake
 pipe.
 Slide the rubber sleeve back to expose the
 starter motor wire nut.
 Remove the starter motor cable nut for
 disconnect the starter motor cable.
 Remove the bolt and then disconnect the
 engine ground cable from starter motor.




                                              Rubber Sleeve           Engine Ground Cable



                                                              Ignition Pulse Generator

 Remove the A.C.Generator and ignition
 pulse generator connectors.




                                                 A.C. Generator Connector


                                                                                         7-4