1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          17. BATTERY/CHARGING SYSTEM                           MXU 500 IRS



 CHARGING VOLTAGE INSPECTION

 Be sure that the battery is in good condition
 before performing this test.

 Do not disconnect the battery or any
   cable in the charging system without first
   switching off the ignition switch. Failure
   to follow this precaution can damage the
   tester or electrical components.

 Start the engine and warm it up to the
 operating temperature; stop the engine.
 Connect the multi-meter between the positive
 and negative terminals of the battery.

 To prevent short, make absolutely certain
 which are the positive and negative terminals
 or cable.
 With the headlight on and turned to the high
 beam position, restart the engine.
 Measure the voltage on the multi-meter when
 the engine runs at 5000 min-1 (rpm).

 Standard:
 Measured battery voltage (page 17-5) <
 Measure charging voltage (see above) <
 15 V




 ALTERNATOR CHARGING COIL

 INSPECTION

 Disconnect the alternator connector.




                                                 Alternator Connector




17-7