1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          18. IGNITION SYSTEM                                                               MXU 500 IRS


TROUBLESHOOTING
LOW PEAK VOLTAGE
 Cranking speed is too low (battery is undercharged).
 Poorly connected connectors or an open circuit in the ignition system.
 Faulty ignition-coil.
 Faulty ignition control module.

NO PEAK VOLTAGE
 Short circuit in engine stop switch or ignition switch wire.
 Faulty engine stop switch or ignition switch.
 Loose or poorly connected ignition control module connectors.
 Open circuit or poor connection in ground wire of the ignition control module.
 Faulty ignition pulse generator.
 Faulty ignition control module.

PEAK VOLTAGE IS NORMAL, BUT NO SPARK JUMPS AT THE PLUG
 Faulty spark plug or leaking ignition coil secondary current.
 Faulty ignition coil.




18-3