1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          16. BRAKE SYSTEM                                                   MXU 500IRS

                                                   Reservoir
 7. Fill the brake reservoir (front brake lever)
    with brake fluid.




                                                               Bleed Valve
 8. Loosen the delay valve bleed valve nut.
    Connect the transparent hose to the bleed
    valve.
    Use the syringe to draw brake fluid into
    it until there is no air bubbles in the
    transparent hose.
    Then, tighten the bleed valve nut.

    Torque: 0.6 kgf-m (6 Nm, 4.32 lbf-ft)

   · When drawing brake fluid with the
     syringe, the brake fluid level should be
     kept over 1/2 of the brake reservoir
     height (front brake lever).
   · Use only the recommended brake fluid.

    Recommended Brake Fluid: DOT-4

                                                   Reservoir

 9. Fill the brake reservoir (brake pedal)
    with brake fluid.