1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          20. LIGHTS/SWITCHES                              MXU 500 IRS


 IGNITION SWITCH

 INSPECTION

 Disconnect the ignition switch connectors.
 (Refer to the "FRAME COVER" section in
 the chapter 2.)

 Check for continuity between the switch
 side connector terminals in each switch
 position.
 Continuity should exist between the color
 coded wires as right:

 REPLACEMENT

 Release the switch wire from the wire clips
 on the steering shaft holder frame pipe.

 Remove the meter cover (refer to the
 "FRAME COVER" section in the chapter
 2).
 Remove the ignition switch from the cover
 while pushing in the two stoppers.

 Install a new ignition switch by aligning the
 locating tab with the groove in the cover.

 Install the removed parts in the reverse
 order of removal.




 HANDLEBAR SWITCH

 INSPECTION

 Remove front center cover (refer to the
 "FRAME COVER" section in the chapter
 2).
 Disconnect the connectors.

 Check for continuity between the switch
 side connector terminals in each switch
 position.
 Continuity should exist between the color
 coded wires as next page:

20-5