mxu 500 irs efi Manuale-dofficina : Pagina 158

Microfiches
Image preview

Pagina 156

Image preview

Pagina 157

Image preview

Pagina 159

Image preview

Pagina 160

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          8. CYLINDER HEAD/VALVES                                                   MXU 500 IRS


                                                 Rocker Arms
 ROCKER ARMS
 REMOVAL/INSPECTION/
 INSTALLATION
 REMOVAL

 Remove the camshafts (refer to the
 "CAMSHAFT REMOVAL/INSPECTION/
 INSTALLATION" section in this chapter).

 Remove the rocker arm shafts and washers,
 then remove the rocker arms.
                                                                Rocker Arm Shafts/Washers

 INSPECTION
                                                 Rocker Arm Shaft
 Rocker arm shaft

 Inspect the rocker arm shaft for blue
 discoloration or grooves.
 If any defects are found, replace the rocker
 arm shaft with a new one, then inspect
 lubrication system.

 Measure each rocker arm shaft O.D.
 Measure the I.D. of each rocker arm.
 Measure arm to shaft clearance.
 Replace as a set if out of specification.

 Service limits: 0.1 mm

 Inspect the rocker arm bore, cam lobe contact                          Rock Arm
 surface and adjuster surface for
 wear/pitting/scratches/blue discoloration.
 If any defects are found, replace the rocker
 arm shaft with a new one, then inspect
 lubrication system.

 Measure each rocker arm shaft O.D.
 Measure the I.D. of each rocker arm.
 Measure arm to shaft clearance.
 Replace as a set if out of specification.

 Service limits: 0.1 mm


8-15