kpw 125 Manuale-dofficina : Pagina 21

Microfiches
Image preview

Pagina 19

Image preview

Pagina 20

Image preview

Pagina 22

Image preview

Pagina 23

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190
          1. GENERAL INFORMATION                                                                       K-PIPE 125


 POOR CHARGING (BATTERY OVER DISCHARGING OR OVERCHARGING)
 Undercharging

 Inspection/Adjustment                         Symptom                       Probable Cause

 Start engine and test
 limit voltage between
 battery terminals

                                                    Voltage does not        Dead battery
                                Normal voltage
                                                    increase                Faulty battery

 Measure resistance
 between AC generator
 coil terminals
                                                                            Faulty coil
                                    Normal          Resistance too high     Broken pink and yellow wires
                                                                            Shorted pink and yellow wires
 Connect battery (+) wire
 to regulator/rectifier
 coupler red wire and
 battery (-) wire to ground
 and test voltage
                                Normal voltage           No voltage         Broken red wire

 Check regulator/rectifier
 coupler for loose
 connection
                                                                            Faulty regulator/rectifier
                                    Normal               Abnormal
                                                                            Poorly connected coupler

                                                                            Faulty A.C. generator

 Overcharging

 Inspection/Adjustment                         Symptom                       Probable Cause

 Connect battery (+) wire
 to regulator/rectifier
 coupler black wire and
 battery (-) wire to ground
 and test voltage
                              Battery has voltage   Battery has no
                              with ignition         voltage with ignition   Broken black wire
                              switch "ON"           switch "ON"

 Check regulator/rectifier
 coupler for loose
 connection


                                   Normal                Abnormal           Poorly connected coupler

                                                                            Faulty regulator/rectifier



1-19