          16. CHARGING SYSTEM                                                                   SPORT CUB 125
                                                                                       K-PIPE 125


  REGULATOR/RECTIFIER
  REMOVAL
  Remove the front cover(page 14-4).
  Remove the regulator/rectifier lock nut and
  disconnect the regulator/rectifier wire
  coupler.
  Measure the resistances between the
  regulator/rectifier wire terminals. Replace
  the regulator/rectifier if the readings are not
  within the specifications in the table below.
                                                      Regulator/Rectifier
· Due to the semiconductor in circuit, it is          Red         Powder color                 Black
     necessary to use a specified tester for
     accurate testing. Use of an improper
     tester or measurements in an improper
     range may give false readings.
     Use a Sanwa Electric Tester or Kowa
     Electric Tester for testing.



                                                                                             Green
                                                      Yellow                         Green



  Testing Range                                       (+)Probe
  Range for the Sanwa Tester: xK                                 Red        Yellow    White     Green
  Range for the Kowa Tester: x100                   (-)Probe

                                                       Red                                       


                                                     Yellow                                    5-100K


                                                     White       3-50                            


                                                     Green                  5-100K      

                                                    Note: The readings in this table are taken with a
                                                    Sanwa Tester.




                                                                                               16-6