1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 407
          4. LUBRICATION SYSTEM                                          MXU 500 IRS


                                                              Dowel Pins
 Remove a bolt and then remove the oil pump
 holder.
 Remove the two dowel pins.

 Remove the two bolts and then remove the oil
 pump.




                                                  Holder       Oil Pump




 INSPECTION

 Oil pump drive chain guide

 Inspect the drive chain slipper surface of the
 drive chain guide for wear or damage.




                                                           Slipper Surface




 INSTALLATION

 Install the oil pump.

 Make sure on the oil pump rotates freely
 and arrow
           the pump shaft
                            is upside.




                                                              Oil Pump