1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 407
          3. INSPECTION/ADJUSTMENT                                                    MXU 500 IRS


 Adjust by loosening the valve adjusting        Wrench Thickness      Gauge Valve Adjusting
 screw lock-nut and turning the adjusting
 screw until there is a slight drag on the
 thickness gauge.

 Valve clearance (when cold):
            IN.: 0.1 mm
            EX.: 0.1 mm

 Apply oil to the valve adjusting screw lock-
 nut threads and seating surface.
 Hold the adjusting screw and tighten the
 lock nut.
                                                                                   Lock Nut
 Special tool:
     Valve adjusting wrench      A120E00036

 Torque: 0.9 kgf-m (9 N-m)

 After tightening the lock nut, recheck the
 valve clearance.

 Install the removed parts in the reverse
 order of removal.




 CARBURETOR IDLE SPEED
    The engine must be warm for accurate
    idle speed inspection and adjustment.

 Warm up the engine before this operation.
 Start the engine and connect a tachometer.
 Turn the throttle stop screw to obtain the
 specified idle speed.

 Idle Speed: 1500100 rpm

 When the engine misses or run erratic,         Throttle Stop Screw
 adjust the pilot screw (refer to the
 "CARBURETOR
 DISASSEMBLY/INSPECTION/
 ASSEMBLY" section in the chapter 5).



                                                                                      3-12