1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 407
          3. INSPECTION/ADJUSTMENT                                                  MXU 500 IRS


 ENGINE OIL REPLACEMENT AND
 OIL FILTER CLEANING

 1. Place the machine on a level place.
 2. Warm up the engine for several minutes
    and stop it.
 3. Place a container under the engine.
 4. Remove the oil filler cap (1).

 Be sure no foreign material enters the                     (1)
   crankcase.




 5. Remove the oil filter cap (2) to drain the
    oil.
 The engine oil will drain more easily
   while the engine is warm.




                                                     Compression Spring           O-ring
 6. Clean the oil strainer with solvent.
    Inspect the O-ring and replace if
    damaged. Reinstall the O-ring, oil
    strainer, compression spring and oil filter
    cap. Tighten the oil filter cap to
    specification.

 Torque: 1.5 kgf-m (15 N-m)

 7. Fill the engine with oil and install the oil
    filler cap.                                      Oil Strainer         Oil Filter Cap

 Engine oil capacity
   At disassembly:
                                         3.6 liter
   At change:
                                        3.0iter




                                                                                   3-14