1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 422
          4. LUBRICATION SYSTEM                              MXU 550EXi/MXU500i



 INSPECTION
 Temporarily install the oil pump shaft.
 Install the outer and inner rotors into the oil
 pump body.

 Measure the tip clearance.

 Service limit: 0.2 mm (0.008 in)
 Measure     at several points and use the
   largest reading to compare the service
   limit.




 Measure the pump body clearance.

 Service limit: 0.25 mm (0.01 in)




 Measure the side clearance with the straight
 edge and feeler gauge.

 Service limit: 0.12 mm (0.0048 in)