1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 422
          3. INSPECTION/ADJUSTMENT                                            MXU 550EXi/MXU500i

                                                Wrench Thickness   Gauge Valve Adjusting
 Adjust by loosening the valve adjusting
 screw lock-nut and turning the adjusting
 screw until there is a slight drag on the
 thickness gauge.

 Valve clearance (when cold):
            IN.: 0.1 mm
            EX.: 0.1 mm

 Apply oil to the valve adjusting screw lock-
 nut threads and seating surface.
 Hold the adjusting screw and tighten the                                       Lock Nut
 lock nut.

 Special tool:
     Valve adjusting wrench A120E00080

 Torque: 0.9 kgf-m (9 N-m)

 After tightening the lock nut, recheck the
 valve clearance.

 Install the removed parts in the reverse
 order of removal.




  IDLE SPEED INSPECTION
    The engine must be warm(80°C over)
    for accurate idle speed inspection

 Warm up the engine before this operation.
 Start the engine and connect a tachometer
 or kymco diagnostic tool.
 attached the specified idle speed.

 Idle Speed: 1400100 rpm
                                                Idle Speed




3-11