1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 433
          14. K-XCT 125 i     FUEL SYSTEM (Auto Control Fuel Injection System)


O2 SENSOR
Measure the resistance of the O2 sensor heater.
(2 white wire pin)

Standard (20°C/68°F ): 6.7 ~9.5




Connect the PDA or KYMCO Fi diagnostic tool.
Into the Data Analyze item .
Check Page 05
(Key switch ON then start engine until O2
heater activation is ON)                                               0~1
If data was incorrect.
It is possible O2 sensor is not normal
                                                                       ON




14-15