1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 433
          12. COOLING SYSTEM                                                          K-XCT 125i




 INSPECTION

 Suspend the thermostat in a pan of water
 over a burner and gradually raise the water
 temperature to check its operation.            Thermostat


 Technical Data
                                                                        Thermometer
    Begins to open     71 1.5°C
    Full-open          80°C
    Valve lift         3.5 mm (0.14 in)
                       minimum

  Do not let the thermostat touch the pan
    as it will give a false reading.
    Replace the thermostat if the valve
    stays open at room temperature.
   Test the thermostat after it is opened for
    about 5 minutes and holds the
    temperature at 70.




 ASSEMBLY

 Thermostat assembly is in the reverse order
 of disassembly.




                                                   Thermostat Housing




                                                                             12-20