1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 433
          12. COOLING SYSTEM                                      K-XCT 125i


 FAN MOTOR SWITCH                                 (1)
 REMOVAL

 Disconnect the fan motor switch connectors

 Remove the thermostat(1).

 INSPECTION

 Place the thermal switch in the stove with
 water as shown and raise the water
 temperature gradually to check for the
 temperature at which the starts to operate.
 If the thermal switch operating temperature
 is not within the specified range, replace the
 thermal switch with a new one.
 OFFON Over 8892C
 ONOFF Lower 8892C
  Handle      the cooling fan motor switch
     carefully as it is vulnerable to impact.



 INSTALLATION

 Change a new O-ring.
 Tighten the cooling fan motor switch to
 specified torque.

 Torque: 1.8 kgf-m (18 N-m, 13 lbf-ft)
  Replace the O-ring a new one.
    Do not use grease to the O-ring.




                                                        12-10