          7. A.C. GENERATOR                                             AGILITY CITY 50 2T


                                               Fan Cover
  A.C. GENERATOR REMOVAL
  Remove the three bolts attaching the fan
  cover to remove the fan cover.




                                                   Bolts



                                                      Bolts
Remove the cooling fan by removing the four
bolts.




                                               Cooling Fan


                                                              Nut
  Hold the flywheel with an universal holder
  and then remove the 10mm flywheel nut.




                                                 Universal Holder


7-3