1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          3. INSPECTION/ADJUSTMENT                          MXU 500 IRS


 COOLING SYSTEM

 COOLANT LEVEL INSPECTION

 Place the machine on the level ground.
 Remove the front center cover (refer to the
 "FRAME COVERS" section in the chapter
 2).

 Check the coolant level in the coolant
 reservoir when the engine is cold as the
 coolant level will vary with engine
 temperature. The level should be between
 the "FULL" (2) and "LOW" (3) level
 surface.
 If the level is low, remove the reserve tank
 cap (1) and fill the tank to the "FULL"
 level line with 1:1 mixture of distilled water
 and antifreeze (coolant mixture preparation:
 refer to the chapter 6 "COOLING
 SYSTEM")

 Using coolant with silicate inhibitors
   may cause premature wear of water
   pump seals or blockage of radiator
   passages. Using tap water may cause
   engine damage.


 Check to see if there are any coolant leaks
 when the coolant level decrease very
 rapidly.
 If reserve tank becomes completely empty,
 there is a possibility of air getting into the
 cooling system.
 Be sure to remove all air from the cooling
 system (refer to the "COOLANT
 REPLACEMENT" section in the chapter
 6).

 Reinstall the filler cap.




                                                        3-30