1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          19. STARTER SYSTEM                                                     MXU 500 IRS

                                                                   Starter MAG
 STARTER RELAY
 SWITCH/STARTER MAG
 INSPECTION

 Turn the ignition switch to "ON".

 Squeeze the brake lever or pedal fully.
 The coil is normal if the starter relay switch
 clicks.

 Squeeze and hold the brake lever or pedal
 fully then push the starter switch.
 The coil is normal if the starter MAG switch                       Starter Relay
 clicks.

 If you do not hear the switch click. Inspect
 the relay switch and starter MAG using the
 procedure below.                                  Starter Relay
 GROUND LINE INSPECTION

 Disconnect the starter relay switch connector.
 Check for continuity between the Green wire
 terminal and ground.

 There should be continuity.




 VOLTAGE INSPECTION

 Connect the starter MAG connector.
 Turn the ignition switch ON.

 Measure the starter MAG Yellow/Red wire
 terminal and ground.

 If the battery voltage appears only when the
 rear brake lever is squeezed fully (or the gear
 change switch in neutral) and starter switch is
 pushed, the circuit is normal.

                                                                       Starter MAG


                                                                              19-4