1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          17. BATTERY/CHARGING SYSTEM                                                   MXU 500 IRS


 INSTALLATION
 Install the stator and tighten the stator mount
 bolts to the specified torque.

 Torque: 1.2 kgf-m (12 N-m)

 Apply sealant to the grommet seating surface
 and install it to the cover groove properly.

 Install the pulse coil and tighten mount bolts
 to the specified torque.

 Torque: 1.2 kgf-m (12 N-m)
                                                        Stator   Grommet                   Pulse



                                                                              Dowel Pins
 Clean the mating surfaces of the right
 crankcase and cover.

 Install the dowel pins and gasket.




                                                      Gasket



 Install the right crankcase cover and tighten
 the bolts in a crisscross pattern in 2 or 3 steps.

 FLYWHEEL:
   Refer to the "STARTER CLUTCH
   REMOVAL/INSPECTION/INSTALL
   ATION" section in the chapter 19




                                                                    Right Crankcase Cover


17-13