1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          17. BATTERY/CHARGING SYSTEM                                                      MXU 500 IRS

 BATTERY CHARGING
 · This model comes with a maintenance free (MF) battery. Remember the following about MF
   batteries.
   Use only the electrolyte that comes with the battery.
   Use all of the electrolyte
   Seal the battery properly
   Never open the seals again
 · For battery charging, do not exceed the charging current and time specified on the battery. Using
   excessive current or extending the charging time may damage the battery.

 SPECIFICATIONS
                                  ITEM                                       SPECIFICATIONS
                       Capacity                                          12V ­ 18 Ah
                       Current leakage                                   0.5 Ma max.
                       Voltage (20°C/68°F)       Full charged            13.0 ­ 13.2 V
 Battery                                         Needs charging          Below 12.3 V
                       Charging current          Normal                  1.8 A/5 ­ 10 h
                                                 Quick                   9 A/1 h
 Alternator            Capacity                                          310 ­ 400 W/5000 rpm
                       Charging coil resistance (20°C/68°F)              0.1 ­ 0.3 




17-3