1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          9. CYLINDER/PISTON                                   MXU 500 IRS


 Cylinder
 Check the cylinder for warpage with a
 straight edge and feeler gauge in the
 directions shown.

 Service Limit: 0.05 mm (0.002 in)




 Check the cylinder wall for wear or damage.
 Measure and record the cylinder I.D. at three
 levels in an X and Y axis. Take the maximum
 reading to determine the cylinder wear.              TOP

 Service Limit: 92.1 mm (3.684 in)                    MIDDLE

 Calculate the piston-to-cylinder clearance.          BOTTOM
 Take a maximum reading to determine the
 clearance.

 Service Limit: 0.1 mm (0.004 in)

 Calculate the taper and out-of-round at three
 levels in an X and Y axis. Take the maximum
 reading to determine them.

 Service Limit:
                  Taper: 0.1 mm (0.004 in)
                  Out-of-round: 0. 1 mm (0.004 in)




                                                            9-6