1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          9. CYLINDER/PISTON                                        MXU 500 IRS


 Piston/Piston pin
 Measure the piston O.D. at the point (A) from
 the bottom and 90° to the piston pin hole.
                                                    (A)
                                                 10 mm
 Service Limit:
            91.9 mm (3.676 in) at (A): 10 mm

 Calculate the cylinder-to-piston clearance.




 Measure the piston pin hole. Take the
 maximum reading to determine the I.D..

 Service Limit: 22.04 mm (0.8816 in)




 Measure the piston pin O.D. at piston and
 connecting rod sliding areas.

 Service Limit: 21.96 mm (0.8784 in)

 Measure the piston-to-piston pin clearance.

 Service Limit: 0.02 mm (0.001 in)




9-5