1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435 440 445 448
          6. COOLING SYSTEM                                                   MXU 500 IRS

                                                      Radiator Cap
 REPLACEMENT/AIR BLEEDING


 Remove the front center cover and right
 footboard (refer to the "FRAME
 COVERS" section in the chapter 2).
 When filling the system or reserve tank
   with coolant (checking the coolant
   level), place the machine in a vertical
   position on a flat, level surface.

 Remove the radiator cap.



                                                             Bypass Hose
 Loosen the hose band
 Disconnect the bypass hose from water
 pump or remove the drain plug and drain
 the coolant from the system.




                                                Drain Plug                 Band



                                             Reserve Tank Cap
 Remove the reserve tank cap and drain the
 coolant from the reserve tank.

 Reconnect the bypass hose securely.




                                                                    Reserve Tank


                                                                                  6-6