          4. LUBRICATION SYSTEM                                             Downtown 300i ABS




 Remove two oil pump mounting bolts and the
 oil pump.
                                                                         Arrow Mark

 OIL PUMP INSTALLATION
 Install the oil pump into the crankcase.

 Install the oil pump with the arrow on the
    pump body facing up and fill the oil pump
    with engine oil before installation.


                                                                     Pump Shaft
 After the oil pump is installed, tighten the two
 mounting bolts.
 Install the pump driven gear and drive chain
 by aligning the pump driven gear with the
 cutout in the pump shaft.
 Install and tighten the pump driven gear bolts.

 Install the oil separator cover and tighten the
 bolts.




                                                             Oil Separator Cover

 Install the starter idle gear and starter clutch.
                                                     Starter Idle Gear
 Install the gasket and dowel pins.

 Install the right crankcase cover and tighten
 the twelve bolts.

 Torque: 1.2 kg-m


 Diagonally      tighten the bolts in 2  3
   times.
                                                                 Dowel Pin